| Brand Name: | Hailos |
| Model Number: | L07 |
| MOQ: | 1 |
| Price: | $3000~$8000 |
| Delivery Time: | 5-8 weeks |
| Payment Terms: | T/T |
| No. | Description | In Row Inverter Compressor PAC | |||||||
| 1 | Model | L07 | |||||||
| 2 | Unit performance | Air volume (m³/h) | 2300 | ||||||
| 3 | Cooling capacity (kW) | 8.1KW | |||||||
| 4 | Number of compressors (units) | 1 | |||||||
| 5 | Operating mode | Constant temperature and humidity type | |||||||
| 6 | Compressor type | Inverter Rotary Compressor | |||||||
| 7 | External static pressure (Pa) | 50--300 | |||||||
| 8 | Power supply (V) | Single phase 230VAC 60HZ | |||||||
| 9 | refrigerant | R410A | |||||||
| 10 | Expansion valve | Electronic expansion valv | |||||||
| 11 | Electric heating type | PTC | |||||||
| 12 | Electric heating power (kW) | 4 KW | |||||||
| 13 | Humidifier type | wet film | |||||||
| 14 | Humidification rate (kg/h) | 3 kg | |||||||
| 15 | Humidification Power (kw) | 0.5 | |||||||
| 16 | Temperature control range (°C) | 17—30 | |||||||
| 17 | Humidity control range (RH%) | 45—75 | |||||||
| 18 | Temperature control accuracy (°C) | ±2 | |||||||
| 19 | Humidity control accuracy (RH%) | ±5 | |||||||
| 20 | Indoor unit | Evaporator type | Copper tube with aluminum fins | ||||||
| 21 | air filter | G4 Level Initial Effect | |||||||
| 22 | Indoor fan type | EC fan | |||||||
| 23 | External dimensions (mm) | W | 300 | ||||||
| 24 | D | 1200 | |||||||
| 25 | H | 2000 | |||||||
| 26 | Unit weight (Kg) | 160 | |||||||
| 27 | outdoor unit | Condenser type | Copper tube with aluminum fins | ||||||
| 28 | Number of outdoor units (units) | 1 | |||||||
| 29 | Outdoor unit weight (Kg) | 60 | |||||||
| 30 | External dimensions (mm) | W | 960 | ||||||
| 31 | D | 280 | |||||||
| 32 | H | 800 | |||||||
| 33 | other | Indoor unit air supply method | Front Horizontal air supply | ||||||
| 34 | Gas tube dimensions (φmm) | 12 | |||||||
| 35 | Liquid tube dimensions (φmm) | 10 | |||||||
| 36 | Recommended to use the main cable. | 3*4²+2*2.5² | |||||||
| 37 | Cables are used to connect indoor and outdoor units. | 3*1.5² | |||||||
| 38 | Humidifier Inlet Water Pipe (φmm) |
20 | |||||||
| 39 | Condensate Drain Pipe (φ mm) | 25 | |||||||
| 40 | Remote control system interface | RS485 | |||||||
| 41 | It has a power failure memory function | Automatic power-on after power failure and reset | |||||||
![]()
![]()
![]()
![]()
![]()
![]()